Model X3 Chilled Mirror Hygrometer Sensor

The Edgetech Instruments Model X3 chilled mirror sensor is specifically designed to measure the Dew/Frost point in demanding process and laboratory applications. It is available in multiple configurations to accurately measure very low dew/frost points in aggressive background gases. The Model X3 Sensor’s minimized sample cavity results in rapid dry-down times, fast response and quick detection of upset process conditions. …

Features

  • Chemically resistant sensor housing and mirror eliminate sensor failures when measuring dew/frost point in aggressive background gases
  • Chamber design and high efficiency heat exchanger result in the ability to measure very low frost points
  • Hinged cover plate allows easy access to the mirror for cleaning and inspection
  • Reduced cavity sample chamber speeds sample sweeping resulting in rapid dry-down after exposure to high moisture levels
  • Rugged, industrial electrical connectors and easy access slim line signal harness simplify installation and maintenance

DewTech 390 Low Dew Point Hygrometer

Ultra-Low Dew Point Capability Measures dew/frost points as low as –90°C with ±0.1°C accuracy using chilled mirror technology. No Recalibration Required Long-term measurement stability eliminates frequent recalibration, reducing maintenance costs. Fast, Repeatable, Reliable Responds quickly to changes in humidity with ±0.05°C repeatability and negligible hysteresis. Fully Scalable Output Multiple analog and digital outputs available for integration into lab systems and …

PDM75-X3 Portable

PDM75-X3SF Portable Dewpoint Hygrometer

Key Benefits Field-Ready, Primary-Method Accuracy Get true chilled mirror dew/frost point measurement—ideal for spot checks, audits, and critical moisture verification. Designed for Harsh Industrial Use Chemically resistant sensor materials and a rugged portable case support real-world environments from plant floors to compressor rooms. Low Maintenance & Easy Mirror Access Flip-top mirror access and Automatic Balance Control reduce service time and …

Sentry Compressed Air Monitoring and Alarm System Data Sheet

SENTRY Compressed Air Monitor and Alarm

The Edgetech Instruments SENTRY turn-key measurement and alarm system features a smart multi-sense probe that continuously monitors the dew/frost point and pressure of compressed air systems to detect compressor or dryer failures and system pressure leaks. The SENTRY features a strobe lamp and pulsing horn plus an alarm relay contact that activate when a programmable, low pressure or high dew/frost …

Features

  • Detects upset conditions in compressed air systems
  • Constantly monitors pressure and dew/frost point temperature
  • Strobe lamp and pulsing audible alarms for low pressure or high dew/frost point alert
  • Displays dew/frost point and pressure on panel meter
  • NIST traceable calibration certificate
  • Field replaceable Smart Sensor Tip
  • Alarm relay and 4 to 20 mA outputs
  • Complete system, ready for installation

HP125 Series Relative Humidity Probe

Measure 4 Parameters with One Probe Simultaneously captures RH%, temperature, dew/frost point, and pressure (absolute or barometric). No Downtime for Recalibration Replace the smart sensor tip in seconds—each is pre-calibrated and ships with a NIST-traceable certificate. Built for Real-World Use Designed for in-situ measurements in compressed air systems, labs, and environmental testing setups. Modular & Flexible Works as a standalone …

DPS3 Heated Dewpoint System

The Edgetech Instruments DPS Series is a heated dewpoint hygrometer that can measure dewpoints up to 95 °C (203°F) and as low as -35 °C (-31°F). This integrated system includes a microprocessor based electronics, a chilled mirror dewpoint sensor, a sample flow meter/valve, assorted tubing and fittings all contained in a heated, temperature controlled NEMA-4 enclosure. The DPS Series heated …

Features

  • Heated dewpoint hygrometer system for measuring dewpoints up to +95°C in high dewpoint gases
  • Solves the high dewpoint measurement problem by heating all system components to a temperature above the dewpoint temperature of the sampled gas, preventing condensation in the measurement system
  • Chilled mirror sensor provides high accuracy over the entire dew/frost range of +95°C to -35°C.
  • Automatic Balance Control mode provides correction for optics contaminants
  • Integrated DPS system contained in a NEMA-4 enclosure with alarm relays and continuous digital and analog outputs
  • Three models available, the DPS3 stand-alone, DPS4 with pressure compensation and the DPS5 with external DewMaster Hygrometer

CAM Compressed Air Module

The CAM (Compressed Air Module) is a sampling chamber for use with Edgetech Instruments humidity and dewpoint probes. It has a sample inlet ball valve for connection to a pressurized compressed air or gas takeoff point, providing an easy way to connect a probe or alarm module to a gas supply. The ball valve allows isolation of the probe from …

Features

  • Sample chamber allows safe isolation and servicing of sensor probe at pressurized sample takeoff point
  • For installation and use with HP125 and Sentry humidity probes
  • Provides ball valve to isolate probe from process pressure and bleeder valve to allow flow of sample gas past the probe sensor
  • May be used for pressure dewpoint or atmospheric dewpoint measurements
  • Available in brass or stainless steel construction