DewTrace Lab Grade Chilled Mirror Hygrometer

The DewTrace is a high precision, bench top, laboratory standard dew/frost point hygrometer capable of measuring very low frost points using the primary method chilled mirror measurement technique. It incorporates novel ice nucleation technology to reach low frost points in minutes, giving it superior performance over a wide dynamic range from ambient to trace moisture concentration levels. Based on the …

Features

  • Chemically resistant, fast response X3 Series sensors
  • Sensors may be liquid or cryogenically cooled
  • Nucleation system for fast, low frost point measurement
  • Automatic Balance Control corrects for mirror contaminants
  • Pressure and temperature sensors included for parameter conversion
  • Operates from ambient conditions to very low frost points

Model DX Chilled Mirror Hygrometer Sensor

The Model DX primary method chilled mirror dew/ frost point sensor is a direct insertion hygrometer sensor with an integral PRT temperature sensor, wide operating range and superior temperature stability. The new DX can be inserted into a gas process stream or used to monitor the local environment. With its integrally mounted temperature sensor, a single penetration reduces installation cost …

Features

  • Direct insertion expands Edgetech Instruments sensor choices for easy installation
  • Integrally mounted PRT temperature sensor reduces installation cost and improves RH accuracy
  • Active sensor temperature compensation and isolation eliminate drift
  • Compact design reduces space needed for installation
  • Integrated micro aspirator option for faster response in static environments
  • Integrated filter options for use in dirty environments

DewMaster Chilled Mirror Hygrometer

Edgetech Instruments field-proven chilled mirror technology.

Features

  • A robust hygrometer for laboratory and industrial applications with field proven reliability and precision
  • Drift free primary method chilled mirror sensors have wide measurement ranges and do not require periodic recalibration
  • ISO/IEC 17025 accredited NIST traceable certification
  • Best in class air cooled temperature depression simplifies operation
  • Automatic Balance Control corrects for contaminants to maintain accuracy
  • Multiple sensor configurations available to fit various applications
  • Desk top, rack mount and NEMA 4X enclosure options available

DewTrak II Chilled Mirror Transmitter

The Edgetech Instruments DewTrak II transmitter is a precision dewpoint hygrometer for industrial and process applications. It measures dew/frost point and relative humidity using a primary method chilled mirror sensor to continuously monitor the water vapor content of gases, and a platinum resistance thermometer to accurately measure temperature, without drift or the need for routine recalibration. The DewTrak II is …

Features

  • Precision dew/frost point or relative humidity transmitter for industrial, process and area monitoring
  • Fast responding primary method chilled mirror sensor with integral PRT retains accuracy without periodic recalibration
  • Remote, insertion or local wall mount sensor configurations to fit application requirements
  • Configurable analog outputs, alarm relays and bi-directional serial interface
  • Bi-directional serial interface
  • Powered by 24 Vdc.

COM.AIR DP Monitor for Compressed Air Systems

The COM.AIR monitor offers the highest level of reliability and accuracy available in compressed air systems dewpoint measurement. It is highly regarded by manufacturing engineers for its robust packaging, accuracy, long life, fast response and ease of use. The COM.AIR employs a chilled mirror sensor, the most accurate commercial dew/frost point sensor type available, to deliver continuous, drift-free dewpoint measurement …

Features

  • Highest level of reliability and accuracy available in compressed air dewpoint measurement
  • Does not require periotic recalibration
  • Uses a chilled mirror sensor to deliver consistent, drift-free measurements without sensor replacement
  • Wide dew/frost point range of -103°F to 122°F (-75°C to 50°C)
  • Rugged NEMA-12 enclosure houses the sensor, control circuitry and flow control
  • Only a sample line and power connection are needed for installation and startup
  • User programmable audible and visible alarms plus relay contact included