Highest level of reliability and accuracy available in compressed air dewpoint measurement
Does not require periotic recalibration
Uses a chilled mirror sensor to deliver consistent, drift-free measurements without sensor replacement
DPS3 Heated Dewpoint System
Heated dewpoint hygrometer system for measuring dewpoints up to +95°C in high dewpoint gases
Solves the high dewpoint measurement problem by heating all system components to a temperature above the dewpoint temperature of the sampled gas, preventing condensation in the measurement system
Chilled mirror sensor provides high accuracy over the entire dew/frost range of +95°C to -35°C.
200M Meteorological Humidity Measurement System
Complete instrument for measurement of atmospheric dewpoint, ambient temperature, relative humidity and other psychrometric variables
For installations requiring continuous, automatic, and unattended measurement of humidity over a very wide range
Certified in an ISO/IEC 17025 accredited laboratory with NIST traceability
DewTrak II MO for Motor Octane Testing
NIST traceable chilled mirror hygrometer continuously monitors motor intake air fuel mix conditions required for Motor Octane Number (MON) and Research Octane Number (RON) testing
Monitors specific humidity and barometric pressure for compliance with test standards ASTM D2700, D2699, D2885
Can be easily fitted to existing knock engine systems
ELH Series – Precision Humidity Chambers
A group of precision calibration chambers incorporating programmable controllers plus primary method DewMaster chilled mirror hygrometers
Highly accurate temperature and humidity control similar in performance to two-pressure method devices but at a significantly lower price
Delivered with multi-point, NIST traceable, ISO/IEC 17025 accredited certification
DewGen – High Accuracy Dewpoint Generator
High accuracy dew/frost point generator for use as a stand-alone device to create a known and precise dew or frost point gas sample
No electric power required, can go wherever needed in the field or in the laboratory, inherently intrinsically safe
Connection to a NIST traceable dew/frost point hygrometer creates a highly accurate and cost-effective dew/frost point generator system
DPM-99 Dewpoint Monitor
Drift free alternative medical air dew/frost point monitoring and alarm system encompassing a chilled mirror hygrometer plus audible and visible alarm functions, contained in a NEMA-12 enclosure
Uses a primary method chilled mirror dew/frost point sensor to meet Level 1 and Level 2 requirements of NFPA 99 for Medical Air
Certified in an ISO/IEC 17025 accredited laboratory traceable to NIST Standards
ATDM Air Temperature Probe
Probe used with relative humidity and dew/frost point hygrometers for temperature measurement
Used to convert humidity parameters when known temperature is required
PT 100 temperature sensor has stainless steel sheath and ten foot connecting cable